• The industry’s First Choice for multi-story heating and cooling.

  • Leading the way in the HVAC industry.

  • A long-term commitment to serving our customers.

  • 1
  • 2
  • 3
Sales Brochures

pdf iconCommercial Product Line Brochure

pdf iconCommercial Product Line Brochure - Water Source Heat Pumps Only

pdf iconClosetline® Brochure

 

Quick Reference Guide

pdf iconQuick Reference Guide - Closetline® WC Compact 1-stage

 pdf iconQuick Reference Guide - Closetline® WR mid-size 1-stage

pdf iconQuick Reference Guide - Closetline® WZ mid-size 2-stage

 

Cut Sheet

pdf iconCut Sheet - Closetline® WC Compact 1-Stage

 Cut Sheet - Closetline® WR Mid-Size 1-Stagepdf icon

pdf iconCut Sheet - Closetline® WZ Mid-Size 2-Stage

 


 

Design Guides

Whalen low GWP IconDesign Guide – Low GWP - Closetline® WC Compact 1-stage Packaged Water Source Heat Pump

 

 Whalen low GWP IconDesign Guide – Low GWP - Closetline® WR Mid-size 1-stage Packaged Water Source Heat Pump

 

Whalen low GWP IconDesign Guide – Low GWP - Closetline® WZ Mid-size 2-stage Packaged Water Source Heat Pump

 

 

pdf iconDesign Guide – Closetline® Horizontal and Vertical Water Source Heat Pump

 

Installation and Operation Manuals

Whalen low GWP IconIOM – Low GWP - Closetline® WC Compact 1-stage Packaged Water Source Heat Pump

 

 Whalen low GWP IconIOM – Low GWP - Closetline® WR Mid-size 1-stage Packaged Water Source Heat Pump

 

Whalen low GWP IconIOM – Low GWP - Closetline® WZ Mid-size 2-stage Packaged Water Source Heat Pump

 

 

pdf iconIOM – Closetline® Horizontal and Vertical Water Source Heat Pump

 

Technical Documents

 pdf iconIO Zone 560 Point List

 

 

Product Specifications

doc iconUnit Specification – Closetline® Fixed Chassis Water Source Heat Pump

doc iconUnit Specification – Closetpack® Classic AC with Hydronic Heat

 

Drawing Files

Closetline® Horizontal Packaged Water Source Heat Pump - CAS Series R-410A

rfa iconRevit® Drawing – Closetline® CAS Series Horizontal Packaged Water Source Heat Pump

Closetline® Vertical Packaged Water Source Heat Pump - CAS Series R-410A

rfa iconRevit® Drawing – Closetline® CAS Series Vertical Packaged Water Source Heat Pump

 

cad iconCAD Drawing – CAS Standard Cabinet - Left Return

cad iconCAD Drawing – CAS Standard Cabinet - Right Return

cad iconCAD Drawing – CAS Hydronic Cabinet - Left Return

cad iconCAD Drawing – CAS Hydronic Cabinet - Right Return

Closetline® Horizontal Water Source Heat Pump

 Closetline CASH Technical Data1

 

Closetline® Vertical Water Source Heat Pump

 Closetline CASV Technical Data1

 


Heating Mode


In the heating mode (Figure 1), hot refrigerant flows through the air coil. The heat pump supplies warm air to the conditioned space. The heat added to the room air is removed from the water flowing through the coil, plus rejected compressor heat.

Whisperline fixed chassis packaged HP 01 heating

Cooling Mode


In the cooling mode (Figure 2), cold refrigerant flows through the air coil. The heat pump supplies cool air to the conditioned space. The heat removed from the room air is transferred to the water flowing through the water coil.

Whisperline fixed chassis packaged HP 01 cooling


 

Compact Footprint

Compact cabinet design with quick access for ease of service. Horizontal units can be serviced through the unit bottom to virtually eliminate removing ceiling mounted units for service.

Fan Operation

Oversized blower for quiet operation. A PSC fan motor is standard for economical operation with an optional constant torque multi-speed EC motor, with soft start and serviceable from one side.

Drain Pan

Internally trapped (vertical models), stainless steel drain pan for years of trouble-free service.

Compressor

Compact and efficient compressors, with double isolation for quiet operation.

Reliable Operation

Thermostatic expansion valve maintains maximum capacity under a wide range of operating conditions.

Coaxial Heat Exchangers

Heavy duty coaxial heat exchanger for reliability. Enhanced internal surface treatment for increased efficiency (CuNi available).

Easy to Install

Water connections are securely mounted flush to the cabinet to eliminate the need for a backup wrench.

Electronic Control Board

Each unit ships with solid state microprocessor controls with safeties built-in for reliable protection.

Built to Last

Satin galvanized and acoustically insulated cabinet for years of quiet operation.

Geothermal Application

Unit capable of operation on a closed loop or a water well installation.

Hot Gas Reheat Option

Hot Gas Reheat is used for humidity control and for occupant comfort. The integrated reheat coil is used to add sensible heat to the air stream to maintain the temperature setpoint and occupant comfort.

 

Whalen Products

Product Line

We manufacture solutions for new and replacement heating and cooling applications.

small arrow Learn More

Applications

Market Applications

We engineer and manufacture vertical stack fan coil units and water source heat pumps for a wide range of applications.

small arrow Learn More

News

Latest News

Visit our newsroom for the latest information about what's happening at the Whalen Company.

small arrow Learn More